OpenSyBY MILLER CONTROLS & SYSTEMS

On-premises cell platform · Miller Controls & Systems

One industrial PC at the cell. Shift OEE on the floor — without changing the PLC program.

OpenSy reads the controllers and drives you already have, computes the shift on the box, and puts pace, downtime, and OEE in front of the operator. The data stays on the premises.

Illustrated plant floor. Not a customer site.

The problem

More tags will not tell you why the line stopped.

The missing layer isn't another tag. It's the ladder itself.

A technician holding a tablet beside a conveyor. The screen is a generic status display. Not a customer site and not a portrait of the founder.
Operators guess reason codes
The reason for a stop is often written down after the fact, from memory, a whiteboard, or a spreadsheet. The controller already saw the stop.
Engineers walk rungs by hand
Finding what the line did still means standing at the cabinet and tracing the program. The count, the state, and the fault are already in the controller.
Dashboards show you were down, not why
A chart of lost time does not say why the line stopped, and it does not put that answer in front of the operator on the shift.
An industrial PC on a DIN rail beside a PLC rack in a cabinet. An illustration, not a shipped hardware model and not a customer cabinet.

How it works

One PC between the controllers and the plant.

OpenSy is installed at the cell. It reads the machine network on one interface and serves the plant network on the other. The PLC program is not changed.

Machine network

First network interface

  • ControlLogix and CompactLogix
  • Kinetix drives
  • Modbus TCP devices
  • PLC-5 and SLC through a 1756-DHRIO
Read only

OpenSy industrial PC

On the premises, at the cell

  • Edge collector
  • OpenCast, the engineer portal
  • OpenView, the operator portal
  • InfluxDB, Grafana, MQTT broker
Web and MQTT

Plant network

Second network interface

  • Operator screens and tablets
  • Engineering workstation
  • MQTT clients and plant historians
The two networks stay on separate interfaces. Nothing on this path writes to a controller or a drive.

Platform

OpenSyBY MILLER CONTROLS & SYSTEMS

The on-premises cell platform from Miller Controls & Systems.

One small industrial PC at the cell. OpenSy reads the controllers you already have, computes the shift, and keeps the data on the premises. OpenCast, OpenView, and SyTrace run on that platform.

Two stacks side by side. The usual stack is a pile of gateways under a cloud. The OpenSy side is one small low-profile industrial PC beside an operator tablet. Caption: the data stays on the premises.

On the platform

OpenCast, OpenView, and SyTrace.

Three products on OpenSy. Set up the cell, run the shift, and ask the ladder why it stopped.

Set up

OpenCast

Find the controller, map the signals the cell already has, set the shift clock and ideal cycle, and publish.

  • Real protocol answer on scan
  • Tag and drive attribute browse before publish
OpenCast topology: OpenSy edge node through a chassis path to a mapped drive. Network addresses are blurred.

Operate

OpenView

Machine state, shift OEE, today’s total against the day target, and the hour chart. Operators log down time and scrap.

  • Machine, line, and plant views
  • Operator tablet for down and scrap
OpenView line screen: shift OEE, availability, performance, quality, and an hour chart for the machines on the line.

Why it stopped

SyTrace

Walk the ladder for why a run is blocked or a fault is latched. Archived .L5X against a live CIP snapshot. Read only. Inside OpenCast.

  • Why stopped and why faulted, locally, no LLM
  • Under 100 ms on active lines
SyTrace causal graph of a ControlLogix program. Node labels are illustrative.

Brownfield first

Read the controllers already on the cell.

Every read is read only. OpenSy does not write controller values, send motion commands, or open an I/O connection to a drive. PLC-5 and SLC are read on DH+ through a 1756-DHRIO.

  • 1 box · 3 PLCs · No tag seats
  • Read only
  • On premises
  • MQTT
  • ControlLogix / CompactLogix / Modbus TCP / Kinetix / PLC-5 & SLC on DH+

ControlLogix and CompactLogix

What is read
Controller tags over EtherNet/IP, direct or routed through a chassis
Test status
Bench and live controller

Kinetix 6500 drives

What is read
Axis attributes: current, bus voltage, velocity, state, faults, motor nameplate
Test status
Run on hardware

Modbus TCP devices

What is read
Holding registers
Test status
Run on hardware

PLC-5 and SLC on DH+

What is read
Data files through a 1756-DHRIO
Test status
Run on hardware
Offline license
A signed file on the industrial PC. No license server, and no connection back to Miller Controls & Systems.
No tag seats
Tags are not licensed by count. There is no tag seat and no factory user meter.
Per node
3 PLCs, or 3 devices, or 6 devices, on the same subnet.

Own test runs

Measured on the bench and on a live controller.

These figures are from Miller Controls & Systems’ own test runs, not from a customer survey. The conditions and the limits of each run are in the test record.

198per second
Samples from one ControlLogix signal read every 5 ms.
2.8ms
Median time from the PLC read to an MQTT subscriber, in that run.
10.0ms
Median read round trip to a live plant welder, routed through a ControlLogix chassis.
0lost
Samples lost between the PLC read and stored history in the 5 ms bench run.

What you buy

One OpenSy node. SyGrid when you need the mesh.

One industrial PC node: OpenCast, OpenView, shift OEE, pace, downtime, and scrap. Each node allows 3 PLCs, or 3 devices, or 6 devices, on the same subnet. The package that unlocks multi-subnet mesh networking and peer-to-peer failover across OpenSy nodes.

Platform

OpenSy

One industrial PC node: OpenCast, OpenView, shift OEE, pace, downtime, and scrap.

3 PLCs, or 3 devices, or 6 devices, on the same subnet

Add-on

SyGrid

The package that unlocks multi-subnet mesh networking and peer-to-peer failover across OpenSy nodes.

SyGrid mesh of synchronized OpenSy nodes with peer latency. Node addresses are blurred.

Unlocks cross-networking and failover

List prices are not published. For a quote, email sales@mcsystems.io. Miller Controls & Systems confirms the price in writing.

From the conversation to a running cell

  1. Step 1

    Quote

    Talk with engineering, or email sales@mcsystems.io. Miller Controls & Systems confirms pricing in writing for your industry and site.

  2. Step 2

    License and software

    The license is issued to your company and site. The software arrives as an installation package for your industrial PC.

  3. Step 3

    Setup

    Your engineer installs the software, maps the signals the cell already has, sets the shift, and publishes in OpenCast. MCS can help with PLC and robot integrations.

  4. Step 4

    Running

    OpenView shows the shift to the floor. MCS does not install or commission the cell on site.

Company

Justin Miller

Founder, Miller Controls & Systems

Miller Controls & Systems wasn't started in a boardroom.

Justin Miller is a former maintenance tech turned controls engineer. It started on plant floors, in maintenance shops, and in front of machines that weren't running — programming the PLCs and the robots, troubleshooting the faults, and explaining why a line missed its numbers. OpenSy is the platform that experience built.

A technician walking a plant floor past an open control cabinet, with an industrial PC sitting at the cell. Not a portrait.
The floor it started on. A portrait of Justin Miller is still to be added.

Talk with Miller Controls & Systems.

Ask about OpenSy for your cell. Send the controllers and the layout — engineering replies. For a quote, email sales@mcsystems.io. Pricing is tailored by industry and site, and confirmed in writing.