Specifications
What is installed, what it connects to, and what it needs.
Planning figures are marked as planning figures. Measured results are in the test record.
Interfaces
Inputs, outputs, and rates.
- Inputs
- ControlLogix and CompactLogix tags over EtherNet/IP. Modbus TCP holding registers. Kinetix 6500 axis attributes. PLC-5 and SLC data files on DH+ through a 1756-DHRIO.
- Outputs
- Named signals on MQTT, as JSON. The broker runs on the industrial PC.
- Machine scan
- Set per machine, down to 0.1 second.
- Fast signals
- Logix numeric tags down to 5 ms. Kinetix attributes down to 100 ms.
- Controller writes
- None. Every read is read only.
- Portals
- OpenCast on port 3001. OpenView on port 3002. Both are served from the industrial PC to a browser.
Platform
Operating system and delivery.
- Linux
- Ubuntu Server or Debian, with Docker Engine.
- Windows
- Windows with Docker Desktop. Timed ControlLogix bench results were measured on Windows 10 Enterprise LTSC; the system has also been run on a Linux plant IPC.
- Processor
- 64-bit x86.
- Delivery
- A versioned installation package with the built software and an installer. Nothing is built on site.
Hardware
The industrial PC you supply.
Miller Controls & Systems sells the software, not the PC. These are planning minimums for a customer-supplied industrial PC, not measured limits.
| Installation | Processor | Memory | Storage |
|---|---|---|---|
| Full system on Linux, minimum | 4 cores | 8 GB | 128 GB |
| Full system on Linux, comfortable | 4 or more cores | 16 GB | 256 GB |
| Full system on Windows, minimum | 4 cores | 16 GB | 256 GB |
Plan for about 500 GB of storage, with 1 TB as the larger option. Two network interfaces are needed to keep the machine network separate from the plant network. Enclosure cooling, power recovery, and drive endurance depend on the site and the model. Hardware companies that want to partner should email info@mcsystems.io.
Storage
InfluxDB live window and overflow.
Full OpenSy includes InfluxDB and Grafana. Live telemetry and events stay about seven days on the industrial PC. Overflow storage routing archives older days to an external drive before they roll off; long retention is limited by that drive’s size. The figures below are planning estimates for the live window only.
| Workload | Growth per day | Seven-day window |
|---|---|---|
| 10 controllers, 20 stored fields each, 2-second scan | 0.4 GB | 2.9 GB |
| One 5 ms fast signal that changes on every read | 3.5 GB | 24.5 GB |
| One 5 ms fast signal that holds its value | 0.02 GB | 0.1 GB |
| 10 controllers plus one always-changing 5 ms signal | 3.9 GB | 27.4 GB |
On the standard 500 GB PC, the largest row is about 9% of the space set aside for history. Actual use depends on the values, the number of stored fields, and how often they change.
Access
Logins, licensing, and the network.
- Floor pages
- OpenView’s machine, line, and tablet pages open without a login on the plant network.
- Engineering pages
- OpenCast setup, accounts, and the license page require an engineer login.
- Accounts
- Engineer accounts are local to the industrial PC.
- License
- A signed file checked on the PC. No license server and no connection back to Miller Controls & Systems.
- Cloud
- Not required. The system can run with no path off the premises.
Questions
What engineering usually asks.
- Does setup change the PLC program?
- No. OpenSy reads the count, state, scrap, and faults the program already has, and computes the shift on the industrial PC.
- Can OpenSy write to a controller?
- No. It does not write tag values, send commands, or open an I/O connection to a drive.
- How long is history kept?
- Live history is seven days in InfluxDB on the industrial PC, with Grafana for trends. The overflow add-on copies older days to an external drive before they roll off; how long you keep them depends on that drive’s size.
- Does it need the internet?
- No. The license is checked on the PC, and the scores are computed there.
- What happens when a package is full?
- A new PLC or device is refused when that OpenSy node is full: 3 PLCs, or 3 devices, or 6 devices, on the same subnet. SyGrid unlocks multi-subnet mesh networking and failover. Another machine on a controller that is already connected is still allowed.
- Who supports it?
- Miller Controls & Systems builds the software and can help with PLC and robot integrations. Your team installs the software and sets up the cell. MCS does not install or commission on site.
Request a quote, or talk it through first.
Email sales@mcsystems.io for a quote. Pricing is tailored by industry and site. Or send the controllers and the cell, and engineering replies.